Data Center Specialized Company

SPECIALIZED SOLUTIONS EXPERT

About

DCiCON Limited is a specialized Data Center Consulting and Engineering firm delivering 25+ consultancy, 15+ design, and 10+ audit projects across enterprises, finance, education, and government sectors. We have led major initiatives in Tier upgrades, new data center builds, migration planning, and GAP assessments, ensuring reliable and standards-aligned infrastructure. With strong expertise in Uptime Institute and EPI (TIA-942) frameworks, we provide vendor-neutral, compliance-driven solutions that enhance efficiency, resilience, and long-term operational performance.

Successful Projects

%

On Time Submission

%

Client Satisfaction

Our Process

Requirement Analysis

On-Site Assessment

Design & Planning

BOQ/BOM

Testing & Validation

Implementation Support

Handover & Documentation

Services

DATA CENTER CONSULTANCY

DATA CENTER CERTIFICATION

DATA CENTER AUDIT

DATA CENTER OPERATION

DATA CENTER TRAINING

DATA CENTER MAINTENANCE

Consultancy Work Showcase

Felicity IDC, ColoCation Data Center [Tier-III]

Scope of Work: Tier-III TCDD & TCCF Consultancy

  • Certification Body: Uptime Institute [TCDD & TCCF]
  • Power Consumption: 2.5 MW (N+N)
  • Cooling System: Water Chiller [N+1]
  • Rack Capacity: 246 Nos
  • Dynamic UPS: 02 nos 1250 KVA DRUPS for one side
  • UPS System: N+N Configuration
  • Chiller System: N+1 Configuration

Felicity BIGDATA, Data Center [Tier-III]

Scope of Work: Felicity Big Data II Ltd, SHSTP, Jessore.

  • Certification Body: Uptime Institute [TCDD]
  • Power Consumption: 2 MW (N+N)
  • Cooling System: Water Chiller [N+1]
  • Rack Capacity: 210 Nos
  • UPS System: N+N Configuration
  • Chiller System: N+1 Configuration
  • Project Statues: Closed due to Building density

BD Police Headquarters Data Center[Tier-III]

Scope of Work: Tier-III Design, Procurement, implementation &  Certification Consultancy

  • Certification Body: Uptime Institute [TCDD & TCCF]
  • 2 Years 24/7 Data Center Operational Monitoring
  • Data Center Audit (IET & IST)
  • Power System: N+N
  • Cooling System: Inrow Cooling[N+N]

bKash Limited Data Center [Tier-III]

Scope of Work: Tier-III Design, Procurement, Implementation &  Certification Consultancy

  • Certification Body: Uptime Institute [TCDD & TCCF]
  • Data Center Audit (IET & IST)
  • Power System: N+N
  • Cooling System: Down Flow [N+1]
  • Rack Capacity: 48 Nos

Sonali Bank PLC Data Center (Tier III)

Scope of Work: Tier-III Design, Procurement, Implementation &  Certification Consultancy

  • Certification Body: Uptime Institute [TCDD & TCCF]
  • Data Center Audit (IET & IST)
  • Power System: N+N
  • Cooling System: Down Flow [N+1]
  • Rack Capacity: 48 Nos

Bangladesh Bank Data Center

Scope of Work: Rated-3 (DCDV) Deign certificate Consultancy

  • Certification Body: EPI [DCDV]
  • Power System: N+N
  • Cooling System: Down Flow (N+1)
  • Rack Quantity:

Bangladesh Army Data Center [Tier-III]

Scope of Work: Tier III TCCF Consultancy services

  • Certification Body: Uptime Institute [TCDD & TCCF]
  • Data Center Audit (IET & IST)
  • Power System: N+N
  • Cooling System: Down Flow [N+1]
  • Rack Capacity: 20 Nos

BRAC University Structured Cabling & Data Center Consultancy

Scope of Work: Structured Cabling Design  10,000+ Node – Copper & Fiber, 168 KW Data Center.

  • Foreign consultant: WOHA DESIGNS PTE LTD, SINGAPORE
  • Data Center  Consultancy & Audit (IET & IST)
  • Power System: N+N
  • Cooling System: Down Flow [N+1]
  • Rack Capacity: 24 Nos

Dhaka Stock Exchange Main Data Center & Near Data Center

Scope of Work: Data Center Design, BOQ, BOM, Tender Specification & Project  Monitoring.

  • Data Center Audit (IET & IST)
  • Power System: N+N
  • Cooling System: Down Flow [N+1]
  • Main DC Rack Capacity: 100 Nos
  • nDC Rack Capacity: 48 Nos

Meghna Bank Data center

Scope of Work : Data Center Consultancy Services to establish and migrate  data Center based on Tier III.

  • Data Center Audit (IET & IST)
  • Power System: N+N
  • Cooling System: InRow [N+1]
  • Rack Capacity: 16 Nos
  • Solution: Whole solution Design Huawei Product including Containment

CERTIFICATION Work Showcase

Felicity IDC, ColoCation Data Center [Tier-III]

Our Tier-III certified data center, designed in line with Uptime Institute’s TCDD & TCCF consultancy standards, delivers robust reliability and efficiency. With a total power capacity of 2.5 MW in an N+N configuration, supported by dual 1250 KVA Dynamic Rotary UPS systems on each side, it ensures uninterrupted operations. Cooling is managed through a water chiller system in N+1 configuration, providing resilient thermal management. The facility houses 246 racks, offering ample capacity for enterprise-scale deployments. By combining redundant power and cooling infrastructure, the data center guarantees high availability and performance for mission-critical workloads.

bKash Limited Data Center [Tier-III]

Our Tier-III data center project encompasses end-to-end design, procurement, implementation, and certification consultancy in alignment with Uptime Institute’s TCDD & TCCF standards. The facility undergoes rigorous audits, including Integrated Equipment Testing (IET) and Integrated System Testing (IST), to ensure compliance and reliability. Built with an N+N power system and a down-flow cooling configuration in N+1 redundancy, the infrastructure is engineered for resilience and efficiency. With a rack capacity of 48, the setup provides secure and scalable hosting for mission-critical operations, backed by robust certification and consultancy expertise.

BD Police Headquarters Data Center[Tier-III]

Our Tier-III data center project covers comprehensive design, procurement, implementation, and certification consultancy in accordance with Uptime Institute’s TCDD & TCCF standards. The facility is supported by two years of continuous 24/7 operational monitoring to ensure reliability and performance. Rigorous audits, including Integrated Equipment Testing (IET) and Integrated System Testing (IST), validate system resilience and compliance. With an N+N power system and inrow cooling also in N+N configuration, the infrastructure is engineered for maximum redundancy and efficiency, providing a highly available environment for mission-critical workloads.

Felicity BIGDATA, Data Center [Tier-III]

Felicity Big Data II Ltd at SHSTP, Jessore was developed under Tier-III design consultancy in alignment with Uptime Institute’s TCDD certification standards. The facility was engineered with a total power capacity of 2 MW in N+N configuration, supported by a fully redundant UPS system. Cooling infrastructure was designed with a water chiller system in N+1 redundancy, complemented by a chiller system also in N+1 configuration. With a rack capacity of 210, the project was structured to deliver resilient and scalable hosting capabilities. However, the project status is marked as closed due to building density constraints.

Sonali Bank PLC Data Center (Tier III)

This Tier-III data center project involves complete design, procurement, implementation, and certification consultancy in accordance with Uptime Institute’s TCDD & TCCF standards. The facility is subject to rigorous audits, including Integrated Equipment Testing (IET) and Integrated System Testing (IST), ensuring compliance and operational resilience. Built with an N+N power system and a down-flow cooling configuration in N+1 redundancy, the infrastructure is engineered for high availability and efficiency. With a rack capacity of 48, the setup provides secure, scalable, and reliable hosting for mission-critical workloads.

Bangladesh Army Data Center [Tier-III]

This Tier-III project focuses on TCCF consultancy services in alignment with Uptime Institute’s TCDD & TCCF certification standards. The scope includes comprehensive data center audits such as Integrated Equipment Testing (IET) and Integrated System Testing (IST) to validate performance and reliability. Designed with an N+N power system and a down-flow cooling configuration in N+1 redundancy, the infrastructure ensures resilience and efficiency. With a rack capacity of 20, the facility is tailored to provide secure, high-availability hosting for specialized workloads.

AUDIT Work Showcase

Felicity IDC, ColoCation Data Center [Tier-III]

Scope of Work: Tier-III TCDD & TCCF Consultancy

  • Certification Body: Uptime Institute [TCDD & TCCF]
  • Power Consumption: 2.5 MW (N+N)
  • Cooling System: Water Chiller [N+1]
  • Rack Capacity: 246 Nos
  • Dynamic UPS: 02 nos 1250 KVA DRUPS for one side
  • UPS System: N+N Configuration
  • Chiller System: N+1 Configuration

Felicity BIGDATA, Data Center [Tier-III]

Scope of Work: Felicity Big Data II Ltd, SHSTP, Jessore.

  • Certification Body: Uptime Institute [TCDD]
  • Power Consumption: 2 MW (N+N)
  • Cooling System: Water Chiller [N+1]
  • Rack Capacity: 210 Nos
  • UPS System: N+N Configuration
  • Chiller System: N+1 Configuration
  • Project Statues: Closed due to Building density

BD Police Headquarters Data Center[Tier-III]

Scope of Work: Tier-III Design, Procurement, implementation &  Certification Consultancy

  • Certification Body: Uptime Institute [TCDD & TCCF]
  • 2 Years 24/7 Data Center Operational Monitoring
  • Data Center Audit (IET & IST)
  • Power System: N+N
  • Cooling System: Inrow Cooling[N+N]

bKash Limited Data Center [Tier-III]

Scope of Work: Tier-III Design, Procurement, Implementation &  Certification Consultancy

  • Certification Body: Uptime Institute [TCDD & TCCF]
  • Data Center Audit (IET & IST)
  • Power System: N+N
  • Cooling System: Down Flow [N+1]
  • Rack Capacity: 48 Nos

Sonali Bank PLC Data Center (Tier III)

Scope of Work: Tier-III Design, Procurement, Implementation &  Certification Consultancy

  • Certification Body: Uptime Institute [TCDD & TCCF]
  • Data Center Audit (IET & IST)
  • Power System: N+N
  • Cooling System: Down Flow [N+1]
  • Rack Capacity: 48 Nos

Bangladesh Bank Data Center

Scope of Work: Rated-3 (DCDV) Deign certificate Consultancy

  • Certification Body: EPI [DCDV]
  • Power System: N+N
  • Cooling System: Down Flow (N+1)
  • Rack Quantity:

Bangladesh Army Data Center [Tier-III]

Scope of Work: Tier III TCCF Consultancy services

  • Certification Body: Uptime Institute [TCDD & TCCF]
  • Data Center Audit (IET & IST)
  • Power System: N+N
  • Cooling System: Down Flow [N+1]
  • Rack Capacity: 20 Nos

BRAC University Structured Cabling & Data Center Consultancy

Scope of Work: Structured Cabling Design  10,000+ Node – Copper & Fiber, 168 KW Data Center.

  • Foreign consultant: WOHA DESIGNS PTE LTD, SINGAPORE
  • Data Center  Consultancy & Audit (IET & IST)
  • Power System: N+N
  • Cooling System: Down Flow [N+1]
  • Rack Capacity: 24 Nos

Dhaka Stock Exchange Main Data Center & Near Data Center

Scope of Work: Data Center Design, BOQ, BOM, Tender Specification & Project  Monitoring.

  • Data Center Audit (IET & IST)
  • Power System: N+N
  • Cooling System: Down Flow [N+1]
  • Main DC Rack Capacity: 100 Nos
  • nDC Rack Capacity: 48 Nos

Meghna Bank Data center

Scope of Work : Data Center Consultancy Services to establish and migrate  data Center based on Tier III.

  • Data Center Audit (IET & IST)
  • Power System: N+N
  • Cooling System: InRow [N+1]
  • Rack Capacity: 16 Nos
  • Solution: Whole solution Design Huawei Product including Containment

Our Vision

To be the leading data center consulting and engineering partner in the region, empowering organizations with resilient, efficient, and standards-aligned digital infrastructure. We aim to advance the reliability of mission-critical facilities through innovation, compliance excellence, and a commitment to delivering long-term value for every client.

Contact Us